Wind Energy

From DolceraWiki
Revision as of 05:54, 9 May 2011 by Abhinandanb (Talk | contribs) (Geographical Distribution)

Jump to: navigation, search

This report presents a brief introduction to wind energy and technologies available for horizontal wind turbines. A detailed taxonomy for horizontal axis wind turbines is presented covering parts of the turbine, control systems, applications among others. A detailed landscape analysis of patent and non-patent literature is done with a focus on Doubly-fed Induction Generators (DFIG) used in the horizontal axis wind turbines for efficient power generation. The product information of major players in the market is also captured for Doubly-fed Induction Generators. The final section of the report covers the existing and future market predictions for wind energy-based power generation.

Error creating thumbnail: /var/www/htdocs/dolcera.com/wiki/includes/limit.sh: line 101: 7407 Aborted /usr/bin/timeout $MW_WALL_CLOCK_LIMIT /bin/bash -c "$1" 3>&-

Error code: 134

Introduction

  • We have been using wind power at least since 5000 BC to propel sailboats and sailing ships, and architects have used wind-driven natural ventilation in buildings since similarly ancient times. The use of wind to provide mechanical power came later.
  • Harnessing renewable alternative energy is the ideal way to tackle the energy crisis, with due consideration given to environmental pollution, that looms large over the world.
  • Renewable energy is also called "clean energy" or "green power" because it doesn’t pollute the air or the water. Wind energy is one such renewable energy source that harnesses natural wind power.

Read More?

Click on Wind Energy Background to read more about wind energy.

In order to overcome the problems associated with fixed speed wind turbine system and to maximize the wind energy capture, many new wind farms are employing variable speed wind energy conversion systems (WECS) with doubly-fed induction generator (DFIG). It is the most popular and widely used scheme for the wind generators due to its advantages.

For variable-speed systems with limited variable-speed range, e.g. ±30% of synchronous speed, the doubly-fed induction generator(DFIG) can be an interesting solution. This is mainly due to the fact that the power electronic converter only has to handle a fraction (20-30%) of the total power as the converters are connected to the rotor and not to the stator. Therefore, the losses in the power electronic converter can be reduced, compared to a system where the converter has to handle the total power. The overall structure of wind power generation through DFIG as shown in the figure below.


Market Research

The History of Wind Energy

  • 3200 BC: Early Egyptians use wind to sail boats on the Nile River
  • 0  : The Chinese fly kites during battle to signal their troops
  • 700s  : People living in Sri Lanka use wind to smelt (separate) metal from rock ore. They would dig large crescent-shaped furnaces near the top of steep mountainsides. In summer, monsoon winds blow up the mountain slopes and into a furnace to create a mini-tornado. Charcoal fires inside the furnace could reach 1200°C (2200°F). Archaeologists believe the furnaces enabled Sri Lankans to make iron and steel for weapons and farming tools.
  • 950 AD: The first windmills are developed in Persia (present-day Iran). The windmills look like modern day revolving doors, enclosed on two sides to increase the tunnel effect. These windmills grind corn and pump water.
  • 1200s  : Europeans begin to build windmills to grind grain. They also built the first post mills out of wood. The Mongolian armies of Genghis Khan capture Persian windmill builders and take them to China to build irrigation windmills. Persian-style windmills are built in the Middle East. In Egypt, windmills grind sugar cane.
  • 1300s  : The Dutch invent the smock mill. The smock mill consists of a wooden tower with six or eight sides. The roof on top rotates to keep the sails in the wind.
.
.
.
  • 1892  : Danish inventor Poul LaCour invents a Dutch-style windmill with large wooden sails that generates electricity. He discovers that fast-turning rotors with few blades generate more electricity than slow-turning rotors with many blades. By 1908, Denmark has 72 windmills providing low-cost electricity to farms and villages.
.
.
.
.
  • 2000s  : North Hoyle, the largest offshore wind farm in the United Kingdom, is built. The Energy Policy Act of 2005 strengthens incentives for wind and other renewable energy sources.

Source: Wind Energy

To know more about the History of Wind Energy, click here

Global Wind Energy Market

Market Overview

  • In the year 2010, the wind capacity reached worldwide 196’630 Megawatt, after 159’050 MW in 2009, 120’903 MW in 2008, and 93’930 MW in 2007.
  • Wind power showed a growth rate of 23.6 %, the lowest growth since 2004 and the second lowest growth of the past decade.
  • For the first time in more than two decades, the market for new wind turbines was smaller than in the previous year and reached an overall size of 37’642 MW, after 38'312 MW in 2009.
  • All wind turbines installed by the end of 2010 worldwide can generate 430 Tera watt hours per annum, more than the total electricity demand of the United Kingdom, the sixth largest economy of the world, and equaling 2.5 % of the global electricity consumption.
  • In the year 2010, altogether 83 countries, one more than in 2009, used wind energy for electricity generation. 52 countries increased their total installed capacity, after 49 in the previous year.
  • The turnover of the wind sector worldwide reached 40 billion Euros (55 billion US$) in 2010, after 50 billion Euros (70 billion US$) in the year 2009. The decrease is due to lower prices for wind turbines and a shift towards China.
  • China became number one in total installed capacity and the center of the international wind industry, and added 18’928 Megawatt within one year, accounting for more than 50 % of the world market for new wind turbines.
  • The wind sector in 2010 employed 670’000 persons worldwide.
  • Nuclear disaster in Japan and oil spill in Gulf of Mexico will have long-term impact on the prospects of wind energy. Governments need to urgently reinforce their wind energy policies.
  • WWEA sees a global capacity of 600’000 Megawatt as possible by the year 2015 and more than 1’500’000 Megawatt by the year 2020.

Source: World Wind Energy Report, 2010

Global Market Forecast

  • Global Wind Energy Outlook 2010, provides forecast under three different scenarios - Reference, Moderate and Advanced.
  • The Global Cumulative Wind Power Capacity is estimated to reach 572,733 MW by the year 2030, under the Reference Scenario
  • The Global Cumulative Wind Power Capacity is estimated to reach 1,777,550 MW by the year 2030, under the Moderate Scenario
  • The Global Cumulative Wind Power Capacity is estimated to reach 2,341,984 MW by the year 2030, under the Advanced Scenario
  • The following chart shows the Global Cumulative Wind Power Capacity Forecast,under the different scenarios:
Global Cumulative Wind Power Capacity Forecast, Source: Global Wind Energy Outlook 2010


Source: Global Wind Energy Outlook 2010

Market Growth Rates

  • The growth rate is the relation between the new installed wind power capacity and the installed capacity of the previous year.
  • With 23.6 %, the year 2010 showed the second lowest growth rate of the last decade.
World Market Growth Rates, Source: World Wind Energy Report, 2010
  • Before 2010, the annual growth rate had continued to increase since the year 2004, peaking in 2009 at 31.7%, the highest rate since 2001.
  • The highest growth rates of the year 2010 by country can be found in Romania, which increased its capacity by 40 times.
  • The second country with a growth rate of more than 100 % was Bulgaria (112%).
  • In the year 2009, four major wind markets had more than doubled their wind capacity: China, Mexico, Turkey, and Morocco.
  • Next to China, strong growth could be found mainly in Eastern European and South Eastern European countries: Romania, Bulgaria, Turkey, Lithuania, Poland, Hungary, Croatia and Cyprus, and Belgium.
  • Africa (with the exception of Egypt and Morocco) and Latin America (with the exception of Brazil), are again lagging behind the rest of the world in the commercial use of wind power.
  • The Top 10 countries by Growth Rate are shown in the figure listed below (only markets bigger than 200 MW have been considered):
Top Countries by Market Growth Rates, Source: World Wind Energy Report, 2010

Geographical Distribution

  • China became number one in total installed capacity and the center of the international wind industry, and added 18'928 Megawatt within one year, accounting for more than 50 % of the world market for new wind turbines.
  • Major decrease in new installations can be observed in North America and the USA lost its number one position in total capacity to China.
  • Many Western European countries are showing stagnation, whereas there is strong growth in a number of Eastern European countries.
  • Germany keeps its number one position in Europe with 27'215 Megawatt, followed by Spain with 20'676 Megawatt.
  • The highest shares of wind power can be found in three European countries: Denmark (21.0%), Portugal (18.0 %) and Spain (16.0%).
  • Asia accounted for the largest share of new installations (54.6%), followed by Europe (27.0%) and North America (16.7 %).
  • Latin America (1.2%) and Africa (0.4%) still played only a marginal role in new installations.
  • Africa: North Africa represents still lion share of installed capacity, wind energy plays hardly a role yet in Sub-Sahara Africa.
  • Nuclear disaster in Japan and oil spill in Gulf of Mexico will have long-term impact on the prospects of wind energy. Governments need to urgently reinforce their wind energy policies.

Source: World Wind Energy Report, 2010

The regional breakdowns for the period 2009-2030 has been provided for the following three scenarios:

  1. Regional Breakdown: Reference scenario (GWEO 2010)
  2. Regional Breakdown: Moderate scenario (GWEO 2010)
  3. Regional Breakdown: Advanced scenario (GWEO 2010)

Note: To know more about the Forecast Scenarios, click here

Company Profiles

  1. Vestas Wind Systems A/S
  2. Suzlon Energy
  3. GE Energy

Doubly-fed Induction Generator: Search Strategy

The present study on the IP activity in the area of horizontal axis wind turbines with focus on Doubly-fed Induction Generator (DFIG) is based on a search conducted on Thomson Innovation.

Control Patents

S. No. Patent/Publication No. Publication Date
(mm/dd/yyyy)
Assignee/Applicant Title
1 US6278211 08/02/01 Sweo Edwin Brush-less doubly-fed induction machines employing dual cage rotors
2 US6954004 10/11/05 Spellman High Voltage Electron Doubly fed induction machine
3 US7411309 08/12/08 Xantrex Technology Control system for doubly fed induction generator
4 US7485980 02/03/09 Hitachi Power converter for doubly-fed power generator system
5 US7800243 09/21/10 Vestas Wind Systems Variable speed wind turbine with doubly-fed induction generator compensated for varying rotor speed
6 US7830127 11/09/10 Wind to Power System Doubly-controlled asynchronous generator

Patent Classes

S. No. Class No. Class Type Definition
1 F03D9/00 IPC Machines or engines for liquids; wind, spring, or weight motors; producing mechanical power or a reactive propulsive thrust, not otherwise provided for / Wind motors / Adaptations of wind motors for special use; Combination of wind motors with apparatus driven thereby (aspects predominantly concerning driven apparatus)
2 F03D9/00C ECLA Machines or engines for liquids; wind, spring, or weight motors; producing mechanical power or a reactive propulsive thrust, not otherwise provided for / Wind motors / Adaptations of wind motors for special use; Combination of wind motors with apparatus driven thereby (aspects predominantly concerning driven apparatus) / The apparatus being an electrical generator
3 H02J3/38 IPC Generation, conversion, or distribution of electric power / Circuit arrangements or systems for supplying or distributing electric power; systems for storing electric energy / Circuit arrangements for ac mains or ac distribution networks / Arrangements for parallely feeding a single network by two or more generators, converters or transformers
4 H02K17/42

IPC Generation, conversion, or distribution of electric power / Dynamo-electric machines / Asynchronous induction motors; Asynchronous induction generators / Asynchronous induction generators
5 H02P9/00 IPC Generation, conversion, or distribution of electric power / Control or regulation of electric motors, generators, or dynamo-electric converters; controlling transformers, reactors or choke coils / Arrangements for controlling electric generators for the purpose of obtaining a desired output
6 290/044 USPC Prime-mover dynamo plants / electric control / Fluid-current motors / Wind
7 290/055 USPC Prime-mover dynamo plants / Fluid-current motors / Wind
8 318/727 USPC Electricity: motive power systems / Induction motor systems
9 322/047 USPC Electricity: single generator systems / Generator control / Induction generator

Concept Table

S. No. Concept 1 Concept 2 Concept 3
Doubly Fed Induction Generator
1 doubly fed induction generator
2 double output asynchronous machines
3 dual fed systems
4 dual feed
5 dual output

Thomson Innovation Search

Database: Thomson Innovation
Patent coverage: US EP WO JP DE GB FR CN KR DWPI
Time line: 01/01/1836 to 07/03/2011

S. No. Concept Scope Search String No. of Hits
1 Doubly-fed Induction Generator: Keywords(broad) Claims, Title, and Abstract (((((doubl*3 OR dual*3 OR two) ADJ3 (power*2 OR output*4 OR control*4 OR fed OR feed*3)) NEAR5 (induction OR asynchronous)) NEAR5 (generat*3 OR machine*1 OR dynamo*1)) OR dfig or doig) 873
2 Doubly-fed Induction Generator: Keywords(broad) Full Spec. (((((doubl*3 OR dual*3 OR two) ADJ3 (power*2 OR output*1 OR control*4 OR fed OR feed*3)) NEAR5 (generat*3 OR machine*1 OR dynamo*1))) OR dfig or doig) -
3 Induction Machine: Classes US, IPC, and ECLA Classes ((318/727 OR 322/047) OR (H02K001742)) -
4 Generators: Classes US, IPC, and ECLA Classes ((290/044 OR 290/055) OR (F03D000900C OR H02J000338 OR F03D0009* OR H02P0009*)) -
5 Combined Query - 2 AND 3 109
6 Combined Query - 2 AND 4 768
7 French Keywords Claims, Title, and Abstract ((((doubl*3 OR dual*3 OR two OR deux) NEAR4 (nourris OR feed*3 OR puissance OR sortie*1 OR contrôle*1)) NEAR4 (induction OR asynchron*1) NEAR4 (générateur*1 OR generator*1 OR machine*1 OR dynamo*1)) OR dfig or doig) 262
8 German Keywords Claims, Title, and Abstract (((((doppel*1 OR dual OR two OR zwei) ADJ3 (ausgang OR ausgänge OR kontroll* OR control*4 OR gesteuert OR macht OR feed*1 OR gefüttert OR gespeiste*1)) OR (doppeltgefüttert OR doppeltgespeiste*1)) NEAR4 (((induktion OR asynchronen) NEAR4 (generator*2 OR maschine*1 OR dynamo*1)) OR (induktion?maschinen OR induktion?generatoren OR asynchronmaschine OR asynchrongenerator))) OR dfig) 306
9 Doubly-fed Induction Generator: Keywords(narrow) Full Spec. (((((((doubl*3 OR dual*3) ADJ3 (power*2 OR output*4 OR control*4 OR fed OR feed*3))) NEAR5 (generat*3 OR machine*1 OR dynamo*1))) SAME wind) OR (dfig SAME wind)) 1375
10 Top Assignees - (vestas* OR (gen* ADJ2 electric*) OR ge OR hitachi OR woodward OR repower OR areva OR gamesa OR ingeteam OR nordex OR siemens OR (abb ADJ2 research) OR (american ADJ2 superconductor*) OR (korea ADJ2 electro*) OR (univ* NEAR3 navarra) OR (wind OR technolog*) OR (wind ADJ2 to ADJ2 power)) -
11 Combined Query - 2 AND 10 690
12 Top Inventors - ((Andersen NEAR2 Brian) OR (Engelhardt NEAR2 Stephan) OR (Ichinose NEAR2 Masaya) OR (Jorgensen NEAR2 Allan NEAR2 Holm) OR ((Scholte ADJ2 Wassink) NEAR2 Hartmut) OR (OOHARA NEAR2 Shinya) OR (Rivas NEAR2 Gregorio) OR (Erdman NEAR2 William) OR (Feddersen NEAR2 Lorenz) OR (Fortmann NEAR2 Jens) OR (Garcia NEAR2 Jorge NEAR2 Martinez) OR (Gertmar NEAR2 Lars) OR (KROGH NEAR2 Lars) OR (LETAS NEAR2 Heinz NEAR2 Hermann) OR (Lopez NEAR2 Taberna NEAR2 Jesus) OR (Nielsen NEAR2 John) OR (STOEV NEAR2 Alexander) OR (W?ng NEAR2 Haiqing) OR (Yuan NEAR2 Xiaoming)) -
13 Combined Query - ((3 OR 4) AND 10) 899
14 Final Query - 1 OR 5 OR 6 OR 7 OR 8 OR 9 OR 11 OR 13 2466(1060 INPADOC Families)

Taxonomy

  • Use the mouse(click and drag/scroll up or down/click on nodes) to explore nodes in the detailed taxonomy
  • Click on the red arrow adjacent to the node name to view the content for that particular node in the dashboard

Sample Analysis

A sample of 139 patents from the search is analyzed based on the taxonomy. Provided a link below for sample spread sheet analysis for doubly-fed induction generators.

Patent Analysis

S. No Patent/Publication No. Publication Date
(mm/dd/yyyy)
Assignee/Applicant Title Dolcera Analysis
Problem Solution
1 US20100117605 05/13/10 Woodward Method of and apparatus for operating a double-fed asynchronous machine in the event of transient mains voltage changes The short-circuit-like currents in the case of transient mains voltage changes lead to a corresponding air gap torque which loads the drive train and transmission lines can damages or reduces the drive train and power system equipments. The method presents that the stator connecting with the network and the rotor with a converter. The converter is formed to set a reference value of electrical amplitude in the rotor, by which a reference value of the electrical amplitude is set in the rotor after attaining a transient mains voltage change, such that the rotor flux approaches the stator flux.
2 US20100045040 02/25/10 Vestas Wind Systems Variable speed wind turbine with doubly-fed induction generator compensated for varying rotor speed The DFIG system has poor damping of oscillations within the flux dynamics due to cross coupling between active and reactive currents, which makes the system potentially unstable under certain circumstances and complicates the work of the rotor current controller. These oscillations can damage the drive train mechanisms. A compensation block is arranged, which feeds a compensation control output to the rotor of the generator. The computation unit computes the control output during operation of the turbine to compensate partly for dependencies on a rotor angular speed of locations of poles of a generator transfer function, so that the transfer function is made independent of variations in the speed during operation of the turbine which eliminates the oscillations and increases the efficiency of the wind turbine.
3 US20090267572 10/29/09 Woodward Current limitation for a double-fed asynchronous machine Abnormal currents can damage the windings in the doubly- fed induction generator. Controlling these currents with the subordinate current controllers cannot be an efficient way to extract the maximum amount of active power. The method involves delivering or receiving of a maximum permissible reference value of an active power during an operation of a double-fed asynchronous machine, where predetermined active power and reactive power reference values are limited to a calculated maximum permissible active and reactive power reference values, and hence ensures reliable regulated effect and reactive power without affecting the power adjustment, the rotor is electrically connected to a pulse-controlled inverter by slip rings with a static frequency changer, and thus a tension with variable amplitude and frequency is imposed in the rotor.
4 US20090008944 01/08/09 Universidad Publica De Navarra Method and system of control of the converter of an electricity generation facility connected to an electricity network in the presence of voltage sags in said network Double-fed asynchronous generators are very sensitive to the faults that may arise in the electricity network, such as voltage sags. During the sag conditions the current which appears in said converter may reach very high values, and may even destroy it. During the event of a voltage sag occurring, the converter imposes a new set point current which is the result of adding to the previous set point current a new term, called demagnetizing current, It is proportional to a value of free flow of a generator stator. A difference between a value of a magnetic flow in the stator of the generator and a value of a stator flow associated to a direct component of a stator voltage is estimated. A value of a preset calculated difference is multiplied by a factor for producing the demagnetizing current.
5 US7355295 04/08/08 Ingeteam Energy Variable speed wind turbine having an exciter machine and a power converter not connected to the grid a) The active switching of the semiconductors of the grid side converter injects undesirable high frequency harmonics to the grid.
b) The use of power electronic converters (4) connected to the grid (9) causes harmonic distortion of the network voltage.
Providing the way that power is only delivered to the grid through the stator of the doubly fed induction generator, avoiding undesired harmonic distortion.
Grid Flux Orientation (GFO) is used to accurately control the power injected to the grid. An advantage of this control system is that it does not depend on machine parameters, which may vary significantly, and theoretical machine models, avoiding the use of additional adjusting loops and achieving a better power quality fed into the utility grid.
6 US20080203978 08/28/08 Semikron Frequency converter for a double-fed asynchronous generator with variable power output and method for its operation Optislip circuit with a resistor is used when speed is above synchronous speed, results in heating the resistor and thus the generator leads to limitation of operation in super synchronous range which results in tower fluctuations. Providing a back-to-back converter which contains the inverter circuit has direct current (DC) inputs, DC outputs, and a rotor-rectifier connected to a rotor of a dual feed asynchronous generator. A mains inverter is connected to a power grid, and an intermediate circuit connects one of the DC inputs with the DC outputs. The intermediate circuit has a semiconductor switch between the DC outputs, an intermediate circuit condenser between the DC inputs, and a diode provided between the semiconductor switch and the condenser. Thus the system is allowed for any speed of wind and reduces the tower fluctuations.
7 US20070210651 09/13/07 Hitachi Power converter for doubly-fed power generator system During the ground faults, excess currents is induced in the secondary windings and flows into power converter connected to secondary side and may damage the power converter. Conventional methods of increasing the capacity of the power converter increases system cost, degrade the system and takes time to activate the system to supply power again. The generator provided with a excitation power converter connected to secondary windings of a doubly-fed generator via impedance e.g. reactor, and a diode rectifier connected in parallel to the second windings of the doubly-fed generator via another impedance. A direct current link of the rectifier is connected in parallel to a DC link of the converter. A controller outputs an on-command to a power semiconductor switching element of the converter if a value of current flowing in the power semiconductor switching element is a predetermined value or larger.
8 US20070132248 06/14/07 General Electric System and method of operating double fed induction generators Wind turbines with double fed induction generators are sensitive to grid faults. Conventional methods are not effective to reduce the shaft stress during grid faults and slow response and using dynamic voltage restorer (DVR) is cost expensive. The protection system has a controlled impedance device. Impedance device has bidirectional semiconductors such triac, assembly of thyristors or anti-parallel thyristors. Each of the controlled impedance devices is coupled between a respective phase of a stator winding of a double fed induction generator and a respective phase of a grid side converter. The protection system also includes a controller configured for coupling and decoupling impedance in one or more of the controlled impedance devices in response to changes in utility grid voltage and a utility grid current. High impedance is offered to the grid during network faults to isolate the dual fed wind turbine generator.
9 US20060192390 08/31/06 Gamesa Innovation Control and protection of a doubly-fed induction generator system A short-circuit in the grid causes the generator to feed high stator-currents into the short-circuit and the rotor-currents increase very rapidly which cause damage to the power-electronic components of the converter connecting the rotor windings with the rotor-inverter. The converter is provided with a clamping unit which is triggered from a non-operation state to an operation state, during detection of over-current in the rotor windings. The clamping unit comprises passive voltage-dependent resistor element for providing a clamping voltage over the rotor windings when the clamping unit is triggered.
10 US20050189896 09/01/05 ABB Research Method for controlling doubly-fed machine Controlling the double fed machines on the basis of inverter control to implement the targets set for the machine, this model is extremely complicated and includes numerous parameters that are often to be determined. A method is provided to use a standard scalar-controlled frequency converter for machine control. A frequency reference for the inverter with a control circuit, and reactive power reference are set for the machine. A rotor current compensation reference is set based on reactive power reference and reactive power. A scalar-controlled inverter is controlled for producing voltage for the rotor of the machine, based on the set frequency reference and rotor current compensation reference.

Click here to view the detailed analysis sheet for doubly-fed induction generators patent analysis.

Article Analysis

S No. Title Publication Date
(mm/dd/yyyy)
Journal/Conference Dolcera Summary
1 Study on the Control of DFIG and its Responses to Grid Disturbances 01/01/06 Power Engineering Society General Meeting, 2006. IEEE Presented dynamic model of the DFIG, including mechanical model, generator model, and PWM voltage source converters. Vector control strategies adapted for both the RSC and GSC to control speed and reactive power independently. Control designing methods, such as pole-placement method and the internal model control are used. MATLAB/Simulink is used for simulation.
2 Application of Matrix Converter for Variable Speed Wind Turbine Driving an Doubly Fed Induction Generator 05/23/06 Power Electronics, Electrical Drives, Automation and Motion, 2006. SPEEDAM 2006. A matrix converter is replaced with back to back converter in a variable speed wind turbine using doubly fed induction generator. Stable operation is achieved by stator flux oriented control technique and the system operated in both sub and super synchronous modes, achieved good results.
3 Optimal Power Control Strategy of Maximizing Wind Energy Tracking and Conversion for VSCF Doubly Fed Induction Generator System 08/14/06 Power Electronics and Motion Control Conference, 2006. IPEMC 2006. CES/IEEE 5th International Proposed a new optimal control strategy of maximum wind power extraction strategies and testified by simulation. The control algorithm also used to minimize the losses in the generator. The dual passage excitation control strategy is applied to decouple the active and reactive powers. With this control system, the simulation results show the good robustness and high generator efficiency is achieved.
4 A Torque Tracking Control algorithm for Doubly–fed Induction Generator 01/01/08 Journal of Electrical Engineering Proposed a torque tracking control algorithm for Doubly fed induction generator using PI controllers. It is achieved by controlling the rotor currents and using a stator voltage vector reference frame.
5 Fault Ride Through Capability Improvement Of Wind Farms Using Doubly Fed Induction Generator 09/04/08 Universities Power Engineering Conference, 2008. UPEC 2008. 43rd International An active diode bridge crowbar switch presented to improve fault ride through capability of DIFG. Showed different parameters related to crowbar such a crowbar resistance, power loss, temperature and time delay for deactivation during fault.

Click here to view the detailed analysis sheet for doubly-fed induction generators article analysis.

Top Cited Patents

S. No. Patent/Publication No. Publication Date
(mm/dd/yyyy)
Assignee/Applicant Title Citation Count
1 US5289041 02/22/94 US Windpower Speed control system for a variable speed wind turbine 80
2 US4982147 01/01/91 Oregon State Power factor motor control system 62
3 US5028804 07/02/91 Oregon State Brushless doubly-fed generator control system 51
4 US5239251 08/24/93 Oregon State Brushless doubly-fed motor control system 49
5 US6856038 02/15/05 Vestas Wind Systems Variable speed wind turbine having a matrix converter 43
6 WO1999029034 06/10/99 Asea Brown A method and a system for speed control of a rotating electrical machine with flux composed of two quantities 36
7 WO1999019963 04/22/99 Asea Brown Rotating electric machine 36
8 US7015595 03/21/06 Vestas Wind Systems Variable speed wind turbine having a passive grid side rectifier with scalar power control and dependent pitch control 34
9 US4763058 08/09/88 Siemens Method and apparatus for determining the flux angle of rotating field machine or for position-oriented operation of the machine 32
10 US7095131 08/22/06 General Electric Variable speed wind turbine generator 25

Top Cited Articles

S. No. Title Publication Date Journal/Conference Citations Count
1 Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation May. 1996 IEEE Proceedings Electric Power Applications 906
2 Doubly fed induction generator systems for wind turbines May. 2002 IEEE Industry Applications Magazine 508
3 Dynamic modeling of doubly fed induction generator wind turbines May. 2003 IEEE Transactions on Power Systems 274
4 Modeling and control of a wind turbine driven doubly fed induction generator Jun. 2003 IEEE Transactions on Energy Conversion 271
5 Ride through of wind turbines with doubly-fed induction generator during a voltage dip Jun. 2005 IEEE Transactions on Energy Conversion 246
6 Dynamic modeling of a wind turbine with doubly fed induction generator July. 2001 IEEE Power Engineering Society Summer Meeting, 2001 196
7 Modeling of the wind turbine with a doubly fed induction generator for grid integration studies Mar. 2006 IEEE Transactions on Energy Conversion 174
8 A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine Sept. 1996 IEEE Proceedings Electric Power Applications 150
9 Doubly fed induction generator model for transient stability analysis Jun. 2005 IEEE Transactions on Energy Conversion 106
10 Control of a doubly fed induction generator in a wind turbine during grid fault ride-through Sept. 2006 IEEE Transactions on Energy Conversion 112

White Space Analysis

  • White-space analysis provides the technology growth and gaps in the technology where further R&D can be done to gain competitive edge and to carry out incremental innovation.
  • Dolcera provides White Space Analysis in different dimensions. Based on Product, Market, Method of Use, Capabilities or Application or Business Area and defines the exact categories within the dimension.
  • Below table shows a sample representation of white space analysis for controlling DFIG parameters with converters, based on the sample analysis.
White Space of converters used to control
Active power
Reactive Power
Decoupled P-Q control
Field oriented control
Direct torque control
Speed control
Frequency Control
Pitch control
PWM Technique
Low voltage ride through
Network fault/Grid fault
Symmetrical and Asymmetrical Faults
Temp control
Grid Side active converters
US20070052394A1

US20060028025A1

US20100148508A1

US20100133816A1 EP2166226A1 US20070132248A1 US20070052394A1 US20100096853A1

US20100114388A1 US20090008938A1 WO2010079234A1

US20090230689A1 US20090206606A1 US20070024247A1

US20090206606A1

US20080129050A1

US20100156192A1

US20070182383A1

US20100002475A1

US20080296898A1 US20070273155A1 US20070278797A1

US20070052244A1

US20070024059A1 US20060238929A1

US20070177314A1 EP2166226A1

US20090121483A1 US20090008938A1

Grid side passive converters
US20030151259A1 US20030151259A1 US20030151259A1
Rotor side converter
US20100142237A1

US20070052394A1 US20060028025A1

US20100096853A1

US20100148508A1 US20100133816A1 US20070132248A1 US20070052394A1

US20100114388A1 US20090008938A1 WO2010079234A1

US20090230689A1 US20070024247A1

US20080129050A1 US20070182383A1 US20100002475A1

US20080296898A1 US20070273155A1 US20070278797A1

US20080157533A1

US20070052244A1 US20070024059A1 US20060238929A1

US20090273185A1

US20070177314A1

US20090121483A1

US20090008938A1

Matrix converters
US20020079706A1 US20070216164A1 US20090265040A1 US20070216164A1

Dolcera Dashboard

Dashboard features.png

Dashboard Link

Doubly Fed Induction Generator - Dashboard
Dashboard thumb.png
  • Flash Player is essential to view the Dolcera dashboard

Products

S. No. Company Product Specifications
1 Vestas V80 Rated Power: 2.0 MW, Frequency: 50 Hz/60 Hz, Number of Poles: 4-pole, Operating Temperature: -30°C to 40°
2 Vestas V90 Rated Power: 1.8/2.0 MW, Frequency : 50 Hz/60 Hz, Number of Poles : 4-pole(50 Hz)/6-pole(60 Hz), Operating Temperature: -30°C to 40°
3 Vestas V90 Offshore Rated Power: 3.0 MW, Frequency: 50 Hz/60 Hz, Number of Poles: 4-pole, Operating Temperature: -30°C to 40°
4 North Heavy Company 2 MW DFIG Rated Power: 2.0 MW, Rated Voltage: 690V, Rated Current: 1670A, Frequency: 50Hz, Number of Poles : 4-pole, Rotor Rated Voltage: 1840V, Rotor Rated Current 670A, Rated Speed: 1660rpm; Power Speed Range: 520-1950 rpm, Insulation Class: H, Protection Class: IP54, Motor Temperature Rise =<95K
5 Gamesa G90 Rated Voltage: 690 V, Frequency: 50 Hz, Number of Poles: 4, Rotational Speed: 900:1,900 rpm (rated 1,680 rpm) (50Hz); Rated Stator Current: 1,500 A @ 690 V, Protection Class: IP 54, Power Factor(standard): 0.98 CAP - 0.96 IND at partial loads and 1 at nominal power, Power Factor(Optional): 0.95 CAP - 0.95 IND throughout the power range
6 Nordex N80 Rated Power: 2.5 MW, Rated Voltage: 690V, Frequency: 50/60Hz, Cooling Systems: liquid/air
7 Nordex N90 Rated Power: 2.5 MW, Rated Voltage: 690V, Frequency: 50/60Hz, Cooling Systems: liquid/air
8 Nordex N100 Rated Power: 2.4 MW, Rated Voltage: 690V, Frequency: 50/60Hz, Cooling Systems: liquid/air
9 Nordex N117 Rated Power: 2.5 MW, Rated Voltage: 690V, Frequency: 50/60Hz, Cooling Systems: liquid/air
10 Converteam DFIG NA
11 Xian Geoho Energy Technology 1.5MW DFIG Rated Power: 1550KW, Rated Voltage: 690V, Rated Speed: 1755 r/min, Speed Range: 975~1970 r/min, Number of Poles: 4-pole, Stator Rated Voltage: 690V±10%, Stator Rated Current: 1115A; Rotor Rated Voltage: 320V, Rotor Rated Current: 430A, Winding Connection: Y / Y, Power Factor: 0.95(Lead) ~ 0.95Lag, Protection Class: IP54, Insulation Class: H, Work Mode: S1, Installation ModeI: M B3, Cooling Mode: Air cooling, Weight: 6950kg
12 Tecowestinghouse TW450XX (0.5-1 KW) Rated Power: 0.5 -1 KW, Rated Voltage: 460/ 575/ 690 V, Frequency: 50/ 60 Hz, Number of Poles: 4/6, Ambient Temp.(°C): -40 to 50, Speed Range (% of Synch. Speed): 68% to 134%, Power Factor (Leading): -0.90 to +0.90 , Insulation Class: H/F, Efficiency: >= 96%
13 Tecowestinghouse TW500XX (1-2 KW) Rated Power: 1-2 kW, Rated Voltage: 460/ 575/ 690 V, Frequency: 50/ 60 Hz, Number of Poles: 4/6, Ambient Temp.(°C): -40 to 50; Speed Range (% of Synch. Speed): 68 to 134%, Power Factor(Leading): -0.90 to +0.90, Insulation Class: H/F, Efficiency: >= 96%
14 Tecowestinghouse TW560XX (2-3 KW) Rated Power: 2-3kW, Rated Voltage: 460/ 575/ 690 V, Frequency: 50/ 60 Hz, Number of Poles: 4/6, Ambient Temp(°C): -40 to 50, Speed Range(% of Synch. Speed): 68 to 134%, Power Factor(Leading): -0.90 to +0.90, Insulation Class: H/F, Efficiency: >= 96%.
15 Acciona AW1500 Rated Power: 1.5MW, Rated Voltage: 690 V, Frequency: 50 Hz, Number of Poles: 4, Rotational Speed: 900:1,900 rpm(rated 1,680 rpm) (50Hz), Rated Stator Current: 1,500 A @ 690 V, Protection Class: IP54, Power Factor(standard): 0.98 CAP - 0.96 IND at partial loads and 1 at nominal power, Power factor(optional): 0.95 CAP - 0.95 IND throughout the power range
16 Acciona AW3000 Rated Power: 3.0MW, Rated Voltage: 690 V, Frequency: 50 Hz, Number of Poles: 4, Rotational Speed: 900:1,900 rpm(rated 1,680 rpm) (50Hz), Rated Stator Current: 1,500 A @ 690 V, Protection Class: IP54, Power Factor(standard): 0.98 CAP - 0.96 IND at partial loads and 1 at nominal power, Power Factor (optional): 0.95 CAP - 0.95 IND throughout the power range
17 General Electric GE 1.5/2.5MW Rated Power: 1.5/2.5 MW, Frequency(Hz): 50/60


Key Findings

Major Players

Major Players

Key Patents

Key Patents

IP Activity

  • Patenting activity has seen a very high growth rate in the last two years.
Year wise IP Activity

Geographical Activity

  • USA, China, Germany, Spain, and India are very active in wind energy research.
Geographical Activity

Research Trend

  • Around 86% patents are on controlling the doubly-fed induction generation(DFIG) which indicates high research activity going on in rating and controlling of the DFIG systems.

Issues in the Technology

  • 86% of the patent on DFIG operation are focusing on grid connected mode of operation, suggesting continuous operation of the DFIG system during weak and storm winds, grid voltage sags, and grid faults are major issues in the current scenario.
Problem Solution Mapping

Emerging Player

  • Woodward is a new and fast developing player in the field of DFIG technology. The company filed 10 patent applications in the field in year 2010, while it has no prior IP activity.

Like this report?

This is only a sample report with brief analysis
Dolcera can provide a comprehensive report customized to your needs

Buy the customized report from Dolcera
Patent Analytics Services Market Research Services Purchase Patent Dashboard
Patent Landscape Services Dolcera Processes Industry Focus
Patent Search Services Patent Alerting Services Dolcera Tools


References

Background References
  1. Wind Energy History
  2. Wind Energy
  3. Wind Energy Basics
  4. How Wind Turbines Work
  5. Different types of wind turbines
  6. Onshore Vs Offshore Wind Turbines
  7. Wind Power
  8. Types of Wind Farms
  9. Offshore Technology
  10. The Fundamentals of Wind Energy
  11. Winder Tower
  12. Wind Towers
  13. Wind Turbine Blades
  14. Wind Turbine Design Styles
  15. Rotor Hub Assembly
  16. Gearbox for Wind Turbines
  17. The Wind Turbine Yaw Mechanism
  18. The Wind Turbine Yaw Mechanism
  19. Wind Turbine Generators
  20. Inside wind turbines
Image References
  1. DFIG Working Principle
  2. Country share of total capacity
  3. Wind turbine principle
  4. Horizontal axis wind turbine
  5. Vertical axis wind turbine
  6. Pitch control
  7. Yaw control
  8. Onshore Wind turbines
  9. Offshore wind turbines
  10. Wind turbine parts
  11. Tower height Vs Power output
  12. Tubular tower
  13. Lattice tower
  14. Guy tower
  15. Tiltup tower
  16. Free stand tower
  17. Single blade turbine
  18. Two blade turbine
  19. Three blade turbine
  20. Internal nacelle structure
  21. Rotor hub
  22. Shaft system
  23. Gear box
  24. Anemometer & Wind vane